The AoKu AKLM-B Series (600VA - 3000VA | AKLM-B-600 to AKLM-B-3000) is an automatic bivolt line-interactive UPS engineered for dual-voltage grid regions (120V/220V AC auto-sensing). Features CPU-controlled 2-step AVR (93-145V / 186-253V input window), 120V/220V AC output, 2–6ms rapid transfer time, built-in lead-acid battery packs (12V 7Ah / 9Ah arrays), auto-restart on AC recovery, offline automatic charging, buzzer mute setup, LED telemetry indicators, and optional RJ11/RJ45 surge protection with USB smart monitoring for commercial workstations, server racks, POS terminals, and security infrastructure.
KEY FEATURES & BENEFITS
Automatic Bivolt Input & Dual Voltage AC Output Adaptability
Engineered specifically for dual-voltage grid infrastructure (120V / 220V AC auto-sensing input). Automatically detects incoming utility voltage across 93–145Vac or 186–253Vac windows, delivering regulated 120Vac or 220Vac output without requiring manual voltage switching or external transformers.
CPU-Controlled 2-Step Automatic Voltage Regulation (AVR)
Integrated Digital CPU microcontroller manages a double-stage AVR boost and buck circuit. Smooths out severe voltage sags and power surges automatically, maintaining stable 120V/220V AC output to connected equipment without discharging internal backup batteries during routine grid fluctuations.
Heavy-Duty Internal Lead-Acid Battery Array (2–6ms Transfer Time)
Houses high-capacity 12V 7Ah or 12V 9Ah internal sealed lead-acid battery packs (ranging from 1 to 4 pcs). Delivers ultra-fast 2–6ms typical transfer time to PWM inverter mode upon utility failure, preventing cashier freezes, server crashes, or data corruption.
Offline Automatic Charging & Auto-Restart on AC Recovery
Intelligent offline charging automatically recharges internal batteries to 90% capacity within 4 to 6 hours even when the UPS unit is powered off. Features seamless Auto-Restart logic, automatically booting up connected loads as soon as AC mains power is restored after long blackouts.
Comprehensive Triple Circuit Protection & Mute Function
Equipped with hardware protection against battery low-voltage discharge, output overload, and short circuits. Features a convenient silence setup button to mute audible buzzer alarms during night-time operation or quiet office environments.
3-LED Status Telemetry Panel & Optional USB/Network Protection
Front panel integrates clear BACKUP (Red), NORMAL (Green), and OVERLOAD (Yellow) LED status indicators for instant operational visual inspection. Supports optional RJ11/RJ45 line surge protection and USB communication port for smart telemetry monitoring.
PRODUCT SPECIFICATIONS
| Technical Parameter | AKLM-B-600 | AKLM-B-1000 | AKLM-B-1200 | AKLM-B-1500 | AKLM-B-2000 | AKLM-B-3000 |
|---|---|---|---|---|---|---|
| ⚡ System Capacity & Power Ratings | ||||||
| Apparent Power (VA) | 600 VA | 1000 VA | 1200 VA | 1500 VA | 2000 VA | 3000 VA |
| Active Power (Watts) | 360 W | 600 W | 720 W | 900 W | 1200 W | 1800 W |
| Topology & Control | Line Interactive Topology ; CPU Controlled Digital Microcontroller Architecture | |||||
| 🔌 AC Input & Automatic Bivolt AVR Parameters | ||||||
| Input Voltage Architecture | Automatic Bivolt Input (120Vac / 220Vac Auto Sensing) | |||||
| Input Voltage Window | 120Vac Mode: 93 – 145 Vac | 220Vac Mode: 186 – 253 Vac | |||||
| Input Frequency Window | 50 Hz / 60 Hz (Automatic Frequency Sensing) | |||||
| AVR Voltage Regulation | 2 Steps Automatic Voltage Regulation (Double Boost & Buck CPU Control) | |||||
| ⚙️ AC Output & Inverter Parameters | ||||||
| Nominal Output Voltage | 120Vac or 220Vac (Region Dependent Output Voltage) | |||||
| AC Mode Output Window | 120Vac System: 109 – 132 Vac | 220Vac System: 200 – 250 Vac | |||||
| DC Mode Output Regulation | 120Vac ± 5% or 220Vac ± 5% | |||||
| DC Mode Output Frequency | 50 Hz ± 0.5 Hz / 60 Hz ± 0.5 Hz | |||||
| Inverter Waveform (DC Mode) | PWM Simulated Sine Wave Output | |||||
| Transfer Time | Typical 2ms – 6ms (10ms Maximum) | |||||
| 🔋 Battery System & Charging Management | ||||||
| Battery QTY & Capacity | 1 pcs × 12V 7Ah | 2 pcs × 12V 7Ah | 2 pcs × 12V 7Ah | 2 pcs × 12V 9Ah | 4 pcs × 12V 7Ah | 4 pcs × 12V 9Ah |
| DC Battery System Voltage | 12 VDC | 24 VDC | 24 VDC | 24 VDC | 48 VDC | 48 VDC |
| Battery Recharge Period | 4 to 6 hours recover to 90% capacity (Automatic Offline Charging) | |||||
| 📐 Protections, Functions & Physical Indicators | ||||||
| Hardware Safeguards | 1. Battery Low Voltage Protection | 2. Output Overload Protection | 3. Output Short Circuit Protection | |||||
| Automatic System Functions | 1. Auto-Restart on AC Recovery | 2. Silence Setup (Mute Button) | 3. Offline Automatic Battery Charger | |||||
| Visual Status Telemetry | 3 LED Telemetry Panel: BACKUP (Red), NORMAL (Green), OVERLOAD (Yellow) + Power Switch | |||||
| Communication Ports | Optional RJ11 / RJ45 Phone/Data Surge Line Protection & USB Smart Telemetry Interface | |||||
Technical Documentation
Access complete industrial specification layouts, installation blueprints, communication protocol guides, and international compliance certifications.
Technical Catalog
Get the AoKu AKLM-B Series catalog for full electrical specifications, cabinet dimensions, battery configurations, wiring guides, and certifications.
User Manual
Get the AoKu AKLM-B Series user manual for step-by-step installation, wiring diagrams, LCD settings, warning/fault code solutions, and battery maintenance.
PRODUCT APPLICATIONS
Engineered for dual-voltage commercial power grids and critical business equipment, the AoKu AKLM-B Series Bivolt Line Interactive UPS provides reliable power backup across six core operational sectors:
🌎 Dual-Voltage Commercial Offices (Latin America & Brazil)
Ideal for commercial office spaces operating in dual-voltage region grids (such as Brazil and Latin America). Auto-senses 120V or 220V AC input, powering PCs, monitors, printers, and PBX systems seamlessly.
🖥️ High-Performance Workstations & IT Server Racks
Delivers 600VA to 3000VA capacity options with 2-6ms transfer time, protecting engineering design workstations, small server racks, and NAS storage nodes against unexpected blackouts and data corruption.
🛒 Retail Supermarket POS Cashier & Checkout Counters
Prevents retail store checkout counter freezes and transaction loss during grid sags, providing uninterrupted power for barcode scanners, receipt printers, and cash registers.
📹 CCTV Security Surveillance & NVR Recording Systems
Ensures continuous 24/7 video security recording by powering DVR/NVR units, IP cameras, and security monitors through line sags and temporary power grid outages.
📡 Telecom Network Hubs & Fiber Optic Routers
Maintains continuous broadband connectivity by backing up fiber optic modems, Wi-Fi routers, network switches, and VoIP communication gateways during local power cuts.
🎮 Home Entertainment & Gaming PC Setup
Protects high-end gaming desktop PCs, gaming consoles, and smart TVs from voltage spikes, providing clean emergency backup power to safely save progress and shut down properly.
PRODUCT SOLUTIONS
Technical solution architectures engineered by AoKu Energy to overcome dual-voltage grid complexity, severe brownouts, and blackout recovery challenges:
🌐 Dual-Voltage Grid Compatibility Solution
AoKu Solution: Automatic Bivolt input sensing dynamically adapts to 120V or 220V AC utility grids, eliminating manual transformer installation and avoiding equipment damage caused by accidental mis-wiring.
⚡ Severe Brownout & Surge AVR Regulation Solution
AoKu Solution: CPU-controlled 2-step AVR automatically boosts deep sags and bucks over-voltages, keeping output within safe tolerances (120V/220V ±5%) without exhausting battery reserves.
⚡ Fast 2–6ms Transfer Business Continuity Solution
AoKu Solution: Microprocessor-driven ultra-fast 2-6ms switching guarantees zero interruption during AC utility failures, keeping critical servers and POS terminals running without rebooting.
🔄 Unattended Auto-Restart & Offline Fast Charging Solution
AoKu Solution: Auto-restart function reboots connected devices automatically upon AC power restoration, while offline automatic charging recovers 90% battery capacity in 4 to 6 hours even when powered off.
🛡️ Triple Hardware Protection & Low Noise Solution
AoKu Solution: Built-in hardware safeguards against low battery discharge, overload, and short circuits, paired with a silence setup button to eliminate annoying alarm noise in quiet offices.
📊 Optional Network Surge & Smart USB Telemetry Solution
AoKu Solution: Optional RJ11/RJ45 surge line protection guards communication lines against lightning strikes, while USB smart software allows automated graceful server OS shutdown.
Frequently Asked Questions
Global Support & Services
Expert customization and technical assistance for your projects.
Pre-Sales Support
Custom configuration and technical consultation.
Post-Sales Support
24/7 assistance and localized parts support.
Global Warranty
Comprehensive coverage for all our hardware solutions globally.
LEAVE A MESSAGE
If you are interested in our products and want to know more details, please leave a message here, we will reply you as soon as we can.