AoKu AKLS-B Series Automatic Bivolt Line Interactive Pure Sine Wave UPS (1KVA - 3KVA | 120V / 220V Auto Sensing | AKLS-B-1K / 1.5K / 2K / 3K)
AoKu AKLS-B Series

AoKu AKLS-B Series Automatic Bivolt Line Interactive Pure Sine Wave UPS (1KVA - 3KVA | 120V / 220V Auto Sensing | AKLS-B-1K / 1.5K / 2K / 3K)

The AoKu AKLS-B Series (1KVA - 3KVA | 800W - 2400W | AKLS-B-1K / 1.5K / 2K / 3K) is an automatic Bivolt line-interactive pure sine wave UPS system engineered for dual-voltage utility grids (120V / 220V Auto Sensing) and critical loads requiring high-quality power backup. Features PF=0.8 power factor, CPU digital control, 2-stage AVR voltage regulation, pure sine wave output on battery mode, 2–6ms transfer time, auto-restart upon AC recovery, and switchable 1.5A/3A charging current modes. Built with internal 12V 7Ah/9Ah lead-acid battery packs, multi-telemetry LCD display, and comprehensive low-voltage, overload, and short-circuit safeguards for server workstations, medical equipment, and commercial IT infrastructure.

Capacity 1KVA - 3KVA | 120V / 220V
Stock Status In Stock

Frequently Asked Questions

Q1: What is an Automatic Bivolt Line-Interactive UPS and why is it essential for dual-voltage regions?
A1: An Automatic Bivolt UPS intelligently senses and accepts either 120Vac or 220Vac utility grid input voltages (92V-140V or 183V-245V) without requiring manual jumper adjustments or external step-down transformers. In regions like Latin America, Brazil, and international facility sites with mixed 120V/220V distribution grids, the AKLS-B Series automatically adapts to the incoming power source while delivering stable, clean power to connected equipment.
Q2: Why is Pure Sine Wave output critical for servers, workstations, and Active PFC power supplies?
A2: Modern enterprise servers, workstation PCs, medical imaging devices, and high-efficiency power supplies utilize Active Power Factor Correction (Active PFC). Standard simulated square-wave UPS systems can cause Active PFC power supplies to shut down unexpectedly or hum excessively during grid outages. The AKLS-B Series outputs a true, smooth Pure Sine Wave on battery power, ensuring seamless compatibility and hardware longevity.
Q3: How does the 2-Stage AVR (Automatic Voltage Regulation) extend battery service life?
A3: Fluctuating utility grids frequently experience voltage sags and surges. The AKLS-B Series integrates a CPU-controlled 2-stage Boost & Buck AVR circuit that automatically adjusts high or low grid voltages back to safe operating ranges (120V/220V ±5%) in AC mode. By stabilizing voltage electronically rather than switching to battery power during routine grid dips, it preserves internal battery energy and extends overall battery life.
Q4: How do I switch between the 1.5A and 3A charging current modes on the LCD panel?
A4: The AKLS-B Series features an adjustable smart charger. On the front LCD display, a small charging current icon indicates normal 1.5A charging. Users can shortly press the control switch twice to toggle between the 1.5A mode and the 3A large charging current mode. This allows faster recharge times when using higher-capacity battery setups or in locations with frequent rolling blackouts.
Q5: What internal battery configurations are used in the AKLS-B models, and how long does recharging take?
A5: The AKLS-B Series utilizes high-rate sealed lead-acid batteries: AKLS-B-1K uses 2 × 12V 7Ah (24VDC), AKLS-B-1.5K uses 2 × 12V 9Ah (24VDC), AKLS-B-2K uses 4 × 12V 7Ah (48VDC), and AKLS-B-3K uses 4 × 12V 9Ah (48VDC). The integrated charger restores 90% of full battery capacity within 6 to 8 hours and supports automatic offline charging even when the UPS unit is turned off.
Q6: What happens when utility grid power recovers after an extended outage, and what safety protections are built in?
A6: When utility grid AC power is restored after a total blackout, the AKLS-B Series features an Auto-Restart function that automatically turns on the UPS and restores continuous power to connected loads without manual intervention. It also incorporates comprehensive multi-tier safeguards, including input breakers, output overload shutdown (60s @ 110%, 5s @ 120%), output short-circuit protection, and 20ms overcurrent system trip.
CTA Background

Global Support & Services

Expert customization and technical assistance for your projects.

Pre-Sales Support

Custom configuration and technical consultation.

Post-Sales Support

24/7 assistance and localized parts support.

Global Warranty

Comprehensive coverage for all our hardware solutions globally.

LEAVE A MESSAGE

If you are interested in our products and want to know more details, please leave a message here, we will reply you as soon as we can.

*
*